Product Name: K37

Product Number:
K6-1037
Excitation Light Sources:
Medium 1:
Toluene
λAb max. [nm]:
434
ε [M–1 cm–1]:
29500
λEm max. [nm]:
540
QY [%]:
49
Medium 2:
Cholesterol in water
λEm max. [nm]:
540
Medium 3:
Ethanol
λAb max. [nm]:
449
λEm max. [nm]:
630
QY [%]:
0.7
Specs Sheet:
Download

Description

  • Cholesterol and triglycerides sensitive fluorescent probe.

 

Applications

  • Determination of cholesterol and triglycerides in biological liquids [1–5].

[1] SU Patent 1457386 (1988)

[2] SU Patent 1476384 (1989)

[3] Lapshin E.N. et al. Application of fluorescent probes in medical diagnosis. Part 2: A Fluorescent assay for atherogenic lipoproteins. Sov. Medical Reviews. Sect. B:  Physicochemical Aspects  of  Medicine. 1991,  vol.3, part 1, p.p.37-101.

[4] Demyanov G.V. et al. Characteristics of molecular fluorescence of a lipid probe in human blood lipoproteins exposed to synchrotron radiation. Nuclear Instrumens and Methods in Physics Research, Sec. A, 1995, vol.A-359, 342-344.

[5] Akimov A.V. et al. Nuclear Instruments and Methods in Physics Research, Sec. A, 1995, vol. A-359, p.p.345-347.

 

Advantages

  • Highly fluorescent probe.
  • Perfectly suited for excitation with the 405-nm, 436-nm and 470-nm diode lasers.
  • Large Stokes' shift (> 100nm).